C330M-G cooled infrared detector is specially developed for VOCs gas leak detection with the function of converting infrared radiation of target with 3.2~3.5μm wavelength into electrical signal. Its external mechanical interface, optical interface and electronic interface are commonly used and can be expanded. C330M-G can be widely used in atmospheric environment monitoring and gas leakage detection, pollutant discharge, chemical gas detection in petrochemical plants and refineries.
| Model | C330M-G | ||
| Sensitive Material | HgCdTe/MCT | ||
| Resolution | 320×256 | ||
| Pixel Size | 30μm | ||
| Spectral Range | 3.2μm±0.1μm~3.5μm±0.1μm (Cusomizable Range: 3μm~5μm) | ||
| Working Mode | Snapshot; ITR Integration Mode; Windows Mode; Anti-blooming | ||
| Charge Capacity | 36Me-/12Me- | ||
| Dynamic Range | ≥80dB | ||
| Number of Output | 1 or 4; Up to 6.6MHz/per Output | ||
| Typical NETD | 10mK (F1.5) | ||
| Effective Pixel Rate | ≥99.5% | ||
| Response Non-uniformity | ≤8% | ||
| Cryocooler | RS058 | RS058I | LS734 |
| Cooler Type | Integral Rotary Stirling Cooler | Integral Rotary Stirling Cooler | Linear Rotary Stirling Cooler |
| Stable Power Consumption | ≤7W | ≤7W | ≤10W |
| Max. Power Consumption | ≤15W | ≤15W | ≤45W |
| Power Supply | 24V DC | 12V DC | 24V DC |
| Cooling Time | ≤6min30s | ≤7min | ≤5min |
| Size (mm) | 142x58.5x71 | 142×58.5×71 |
Compressor Φ46×122 Dewar Φ40×114 |
| Weight | ≤600g | ≤600g | ≤1.2kg |
| Working Temperature | -45°C ~ +71°C | ||
For more information, please click the button below to download a PDF of the product.
DownloadsGo Top